Intelligent Gas Leakage  : Combustible,toxic gas catalytic Infrared electrochemical Photo ionization Metal dioxide(chemfet mos)

 - Model : HK-7100A
 - Display : OLED(Organic Light Emitting Diode), Two level alarms and fault alarm indicator
 - Operation : magnetic pen & bi-directional infrared remote controller (optional)
 - Measurement : Combustible,toxic gas
 - Principle
 +   : catalytic
 +   : Infrared
 +   : electrochemical
 +   : Photo ionization
 +   : Metal dioxide(chemfet mos)
 - Sample Method : diffusion
 - Measurement Range : Upon customers’requirements
 - Resolution : 1% LEL
 - Accuracy : 3% F.S.
 - Response Time(T90)
 +   : catalytic≤10sec
 +   : Infrared≤15sec
 +   : Metal dioxide(chemfet mos)≤30sec
 +   : Photo ionization≤30sec
 +   : Electrochem:depended on different sensors
 - Alarm Configuration : two levels alarm, the alarm concentration programmable
 - Ambient Temperature : (-40~70)%;C(according to the sensor if electrochemical
 - Ambient Humidity : ≤93%RH (no condensation)
 - Atmosphere Pressure : (86~106) KPa
 - Output : (4~20)mA + BUS(CAN、RS485、HART)(OPTIONAL)
 - Transmission
 +   : (4~20)mA and HART:≤1000m(2.5 mm2)
 +   : CAN BUS:≤10km
 +   : RS485 BUS:≤1.2km
 - Power Supply : DC24V±6V power by controller or individual power
 - Wiring : 2-wire 3-wire 4-wire 
 - Power Consumption : ≤2W
 - Storage Temperature : (-40~85)%;C
 - Anti–explosion Marker : ExdⅡCT6
 - Protection Rating : IP66
 - Applicable Standard : GB15322.1-2003